City of Harrisonburg

Anti-Data Center Policies

Harrisonburg restricts data centers to industrial zones and requires a special-use permit, public hearings, and City Council review, which can delay projects. It does not ban them or set new operating rules.

current law · City of Harrisonburg
This ordinance adds a definition of “Data Centers” to Harrisonburg’s zoning ordinance and excludes ordinary server rooms or information-technology infrastructure that is accessory to another principal use.Harrisonburg City Ordinance Amending and Re-enacting Title 10, Chapter 3, Sections 10-3-24 and 10-3-97 — Data Centers (2025)

What this means

The measure would limit data centers to industrial zones and require a special-use permit, adding public hearings, City Council review, and potential delays; it would also remove some business-zone locations where they were previously allowed (restricted to industrial zones). It does not ban data centers or impose new operating rules, but the narrower siting options and case-by-case approval are meaningful hurdles.

People behind it

  • Enacted and approved the ordinance adding data centers as a special-use-permit use in the M-1 district.

  • Developed the zoning amendment establishing additional regulatory control over data center construction.

Restrictions & requirementsHide restrictions & requirements4
  • Data centers are permitted only in M-1 industrial zoning districts through a special use permit; they are no longer automatically allowed in certain business zones.

  • Building or expanding a data center requires a special use permit, adding a discretionary approval process beyond ordinary zoning approval.

  • A special-use-permit application for a data center requires a public hearing and approval by City Council.

  • Server rooms and information-technology infrastructure that are accessory to a site’s principal use are excluded from the data-center definition and therefore are not covered by these data-center zoning restrictions.

Benefits & exceptionsHide benefits & exceptions2
  • Data centers are expressly permitted in the M-1 industrial district through a special use permit, creating a defined zoning pathway for construction and expansion. The permit process includes public hearings and City Council approval. Data centers

  • The ordinance defines data centers to include supporting infrastructure such as backup batteries, generators, air handlers, water-cooling and storage facilities, utility substations, and other associated utility infrastructure, allowing these components to be treated as part of the data-center use. It does not cover server rooms or information-technology infrastructure that is accessory to a site's principal use. Supporting equipment may include