Loading map…

City of Sabinal

Mixed Data Center Policies

Texas offers substantial tax breaks on equipment and electricity to large projects meeting investment and job requirements, while large grid connections face studies, fees, and possible emergency power cuts; some requirements apply only to very large loads.

Rating and summary from Texas statewide as there are no scored current or future laws outside temporary restrictions for City of Sabinal.

failed · City of Sabinal
Establishes no data-center-specific regulations in Sabinal’s municipal code.No Sabinal data-center-specific laws identified

What this means

The code does not target data centers, but it adds practical costs and requirements: commercial projects outside city limits must provide water rights and arrange utility extensions, and development in flood-risk areas needs a permit and must meet flood-safety rules (commercial customers applying for out-of-city service). These hurdles could make some projects harder, especially large facilities needing substantial water, but the rules do not ban data centers or apply equally to every site.

Restrictions & requirementsHide restrictions & requirements10
  • Until the city adopts a comprehensive zoning ordinance, building-permit applications must first go to the planning and zoning commission for a report and recommendation. The city council may override an adverse recommendation by majority vote; if the commission does not act within 10 days, its recommendation is deemed approved. Permit requests must first be submitted to the commission

  • Plumbing work is subject to the adopted 2015 International Plumbing Code. Plumbers working in the city need a city plumbing-inspector license, a permit before starting each job, and an inspection and approval before the installation or repair is used; license and inspection fees apply. A permit must be secured before starting any job

  • Development in a designated special flood hazard area requires a floodplain development permit. New or substantially improved structures in areas with base-flood data must meet applicable elevation or floodproofing standards, and violations can result in a fine of up to $500 per violation. A floodplain development permit shall be required

  • Water service requires city approval and a permit for connections. Each separate commercial establishment must have its own approved outside-readable meter; multiple connections to one meter are prohibited, and connections must include backflow prevention. The city may disable unauthorized or substandard connections and charge the owner for removal and repair. Multiple connections of water lines to a single meter are not permitted

  • For developers and commercial customers seeking water service outside city limits, each metered connection requires purchasing and donating one acre-foot of Edwards Aquifer water and entering into utility-extension agreements. They may not connect to existing water mains; applications require city-council review and may be denied or conditioned. purchase and donate to the city one (1) acre-foot

  • Commercial establishments must connect to the public sewer unless exempted or granted a waiver, and sewer connections require a city permit and payment of applicable charges. The fee schedule sets a business monthly sewer charge of $21 per connection for up to 10 outlets or drains, with additional charges for more outlets. shall install suitable facilities for conveying

  • Water and related utility charges add costs where a facility uses city services: the schedule sets a $15 monthly in-city water minimum for the first 2,000 gallons, tiered charges for additional use, an $8 Edwards Aquifer management fee, and a $500 in-city or $1,250 out-of-city meter-installation charge. All accounts will be charged a flat $8.00 Edwards Aquifer management fee

  • Where a water connection presents an actual or potential contamination hazard, it must be protected under the city’s cross-connection rules. Required assemblies must be installed, tested, and maintained; health-hazard assemblies require at least annual testing, and water service may be discontinued if required protection is not maintained. tested and certified to be operating within specifications at least annually

  • Noise rules prohibit unreasonable disturbing noise and set maximum levels for sound discernible beyond the property: 85 dB(A) during daytime hours and 70 dB(A) during nighttime hours. exceeds 85 dB(A) during daytime hours and 70 dB(A) during nighttime hours

  • During a Stage 2 moderate water shortage, mandatory restrictions apply, including limits on landscape irrigation and vehicle washing, restrictions on filling pools, and prohibitions on certain nonessential water uses. During Stage 3 severe shortages, hose-end sprinklers are prohibited and irrigation is further limited. Under threat of penalty for violation

Benefits & exceptionsHide benefits & exceptions2
  • Building-permit requests are referred to the Planning and Zoning Commission; if it does not act within 10 days, the request is deemed approved unless the City Council denies it. This provides a time-limited review pathway, subject to council denial and the provision applying only until a comprehensive zoning ordinance is adopted. Commission requests are deemed approved after ten days

  • Developers and commercial customers may apply for water service outside city limits, with utility-main extensions available to support the connection. Conditions include donating one acre-foot of Edwards Aquifer water per metered connection, paying for or agreeing to the required extensions, technical review, and City Council approval; applicants may not connect to existing water mains. Developers and commercial customers applying for out-of-city service

Sources

Cookie preferences · Report missing data