City of Hilshire Village
Strongly Anti-Data Center Policies
Hilshire Village’s enacted zoning ordinance limits C-1 districts to listed office, retail, and food-service uses; because data centers are not listed, they are effectively barred in those districts.
current law · City of Hilshire VillageProhibits data centers in the C-1 commercial district by allowing only professional offices, retail sales, and food and beverage establishments.Ordinance No. 740 (2017), amending Chapter 12 zoning regulations for the C-1 Commercial District
What this means
The measure allows only professional offices or studios, retail sales, and food and beverage service in the C-1 district, and says unlisted uses are not allowed. A dedicated data center is not listed, so the measure would effectively prohibit building or operating one in that district.
People behind it
- Zoning Committee
Developed recommendations for the commercial district and prepared the draft considered by the City Council.
- City Council of the City of Hilshire Village
Considered and adopted the ordinance replacing the C-1 Commercial District regulations.
Restrictions & requirementsHide restrictions & requirements17
In the C-1 Commercial District, only professional offices or studios, retail sales, and food and beverage service establishments are permitted; any use not listed is not allowed. Permitted uses
Before a business can operate or receive a certificate of occupancy, it must obtain City Council site plan approval. The application must include specified plans, including parking, landscaping, lighting, vehicle access, signage, fencing, and screening; Council may approve, conditionally approve, or deny it. Site plan review and approval
An approved business receives a business operation certificate valid for 12 months and must renew it annually. Renewal may be denied for a significant operational change, regulatory noncompliance, or repeated or significant complaints. Twelve-month certificate
A change in the type of business at a location requires a new site plan and an application for a business registration certificate. Change in business type
Business hours are limited to 6:00 a.m. through 10:00 p.m. Operation from 10:00 p.m. to 6:00 a.m. is allowed only by appointment and only if no sound or light from the operation can be seen or heard outside the building. Operating hours
C-1 businesses may not use drive-through services or sales; store, handle, process, or manufacture ammunition or specified dangerous materials; create specified nuisances; or use premises for residential purposes or overnight sleeping. Prohibited activities
Lots must be at least 15,000 square feet. Westview Drive is treated as the front, with 10-foot front and rear setbacks and a 5-foot side setback; structures are limited to 35 feet and two stories, including roof-mounted equipment, and the main building must have at least 1,000 square feet of net ground-floor area. Lot performance standards
Each business must provide onsite parking in a number considered necessary and appropriate for its use, subject to review under engineering and planning practices. Shared parking agreements with adjacent businesses are allowed; individual spaces must meet minimum size and access rules, and accessible spaces are required. Parking plan requirements
No driveway, curb cut, or sign may be oriented toward or connected to Pine Creek Lane. Pine Creek Lane access
A new fence requires a separate permit. Property owners must build and maintain an eight-foot fence on the commercial side of the property line between C-1 and R-3 districts, subject to specified construction and location rules. Fence requirements
At least 10% of each lot must be landscaped and maintained. Plantings within 10 feet of the front property line may be no higher than 3 feet, and hardscaping is limited to 2 feet in that area and 4 feet elsewhere. Landscaping standards
New construction or significant remodeling requires a drainage plan approved by the City Engineer, and at least 20% of gross lot area must be permeable, including the required landscaping area. Drainage and permeable-area requirements
For buildings less than 50 feet from residentially zoned property, ventilation or window openings are prohibited above 10 feet on south elevations. Parapet walls or roof design must conceal mechanical equipment, communication devices, and solar panels from ground-level view. South elevation and equipment screening
New buildings and expansions or renovations affecting 50% or more of an existing building’s total floor area must use masonry for at least 75% of first-floor exterior walls and 50% of second-floor exterior walls, excluding doors and windows. The ordinance excludes several materials, including EIFS, fiber-cement siding, precast concrete panels, plain concrete block, and painted masonry. Building-material thresholds
Outdoor storage or display is prohibited except for garbage cans and dumpsters; garbage cans placed beside a building must be screened from view and protected from scattering. Outdoor storage and display
Lighting may not exceed 20 feet, must be directed away from residentially zoned areas and shielded from spilling onto residential property, and motion- or timer-activated lighting must not be triggered by movement on residential property. Lighting limits
Outside speakers are prohibited, and noise that would disturb a reasonable person is prohibited. Equipment requiring exhaust venting must vent through the roof unless building or safety codes require otherwise. Noise and venting rules