City of Caddo Mills

Neutral Data Center Policies

Hunt County bars data centers from receiving county tax abatements; separate enacted measures support a possible unincorporated-area pause and request a state pause, but do not themselves impose one.

Rating and summary from Hunt County as there are no scored current or future laws outside temporary restrictions for City of Caddo Mills.

failed · City of Caddo Mills
Requires a proposed data center not listed in the zoning ordinance to undergo review so the city can determine where it may be located; the ordinance sets no data-center-specific rules.No data-center-specific regulations identified

What this means

The ordinance does not name data centers, so a proposal may need review and a City Council decision to classify it as a new or unlisted use, adding uncertainty and delay (unlisted uses go to the Council). A data center may fit an industrial district, but it would still need to meet applicable zoning, permitting, and operating standards; the ordinance offers no specific incentives (industrial uses must meet performance standards).

People behind it

  • May initiate or order consideration of zoning amendments and has authority to adopt them.

  • May initiate zoning amendment proposals and reviews applications, holds hearings, and makes recommendations to the City Council.

  • May request a zoning amendment.

Restrictions & requirementsHide restrictions & requirements11
  • Data centers are not expressly listed in the use table. A new or unlisted use must be referred to the Planning and Zoning Commission for a recommendation, and the City Council determines its zoning classification by ordinance (unlisted-use classification process).

  • Land and buildings must conform to the uses allowed in their zoning district; a building permit cannot be issued unless the tract is part of an approved, recorded plat (zoning compliance and plat requirements).

  • A permanent structure requires a building permit before construction and a certificate of occupancy before use. Plans must be approved, and foundation, plumbing, electrical, and framing inspections occur before the certificate is issued (permit and occupancy requirements).

  • If a data center needs a zoning change, the process requires public hearings before the Planning and Zoning Commission and City Council, with advance publication and mailed notice to nearby property owners. If owners of at least 20% of specified nearby or affected area protest, approval requires at least 75% of the Council (zoning-change hearings and protest threshold).

  • A zoning application denied expressly with prejudice cannot be refiled for one year, unless the Planning and Zoning Commission finds changed circumstances sufficient to waive the waiting period (one-year refiling limit).

  • If the use requires a Specific Use Permit, the application must include a scaled site plan and go through public notice and a hearing; the City Council may impose written conditions and must consider compatibility, access, drainage, parking, screening, and public health and safety (SUP application and approval criteria).

  • For a Planned Development, the City Council must approve a conceptual plan and a development or detailed site plan. Separate public hearings are generally required, though the Council may waive one; the initial development plan is due within six months, with an extension of up to six months, or the conceptual plan is subject to reapproval (PD plan and timing requirements).

  • Parking is required under the ordinance’s use-based schedule. For uses not specified, the Administrator may select a similar use to set the minimum parking standard; mixed uses generally require the sum of their separate parking requirements (parking standards and unspecified uses).

  • In M-1, permitted uses must be enclosed except for listed exceptions, must not emit specified nuisance conditions, and may not exceed 55 decibels at the property boundary during business hours (8 a.m. to 6 p.m.) (M-1 operating standards).

  • In M-2, operations must meet applicable smoke and particulate rules; emissions beyond the property line cannot be detrimental to health, safety, or welfare; noise at the property line cannot exceed 75 dB(A) for more than 15 minutes in any hour; and water-pollution safeguards may be required before a certificate of occupancy (M-2 performance standards).

  • The City Council sets fees for permits, certificates, appeals, and other zoning matters, and required fees must be paid before a permit, certificate, or variance is issued or Board of Adjustment proceedings proceed (fees must be paid).

Benefits & exceptionsHide benefits & exceptions3
  • A new or unlisted use can be referred to the Planning and Zoning Commission for a recommendation on its zoning classification, with the City Council making the final determination by ordinance. This provides a possible review route for a data center, but does not guarantee approval or a particular district. Classification of new or unlisted uses

  • A Planned Development (PD) district allows the City Council to specify permitted uses and set tailored development standards, with flexibility in land and building design. Establishing a PD requires plan review and City Council approval, so this is a discretionary route rather than automatic permission. PD permitted uses and standards

  • A use or structure that was lawfully operating before it became nonconforming may retain nonconforming status. It may not be expanded, and nonconforming rights end if the use is abandoned; six months of business discontinuance or vacancy is conclusive proof of intent to abandon. Nonconforming uses and structures