City of Sharon

Neutral Data Center Policies

Sharon allows data centers by exception in the M-3 district, subject to performance rules, cooling and water limits, noise testing, and funds for eventual removal.

Incentives

Financial Incentive
2

Financial incentives not assessed from full ordinance text in this tracker import; an empty list is not a confirmed finding that no incentive exists.

Financial incentives not assessed from full ordinance text in this tracker import; an empty list is not a confirmed finding that no incentive exists.

current law · City of Sharon
Allows data centers and related accessory uses in Sharon’s M-3 district by exception, subject to new performance standards.Ordinance 08-26 – Data Center

What this means

The measure would create a path for data centers in the M-3 district, but only by exception and subject to performance rules (permitting them by exception in M-3). That balances new permission with limits on where and how they can operate, so the overall effect appears roughly neutral.

Restrictions & requirementsHide restrictions & requirements2
  • Data centers and data center accessory uses are allowed by exception in the M-3 zoning district, rather than as an unrestricted permitted use.

  • The ordinance adds performance criteria for data centers and data center accessory uses; the provided sources do not specify the criteria.

Benefits & exceptionsHide benefits & exceptions1
  • Permits data centers and accessory data center uses by exception in the M-3 zoning district, subject to the ordinance’s performance criteria. The agenda describes the M-3 exception and performance criteria.

Sources

current law · City of Sharon
Allows data centers and related accessory uses in M-3 zones only by exception, subject to data-center-specific performance standards.Sharon Ordinance No. 08-26 — Data Center Zoning Ordinance

What this means

The measure would make data centers eligible in the M-3 district, creating a new path to build them, but only by exception and subject to performance rules (permitted by exception in the M-3 district). This is a modest expansion, balanced by review and operating requirements.

Restrictions & requirementsHide restrictions & requirements2
  • Data centers and data-center accessory uses require approval by exception in the M-3 zoning district under the amendment, adding a land-use approval step. Permitting said uses by exception in the M-3 Zoning District.

  • The amendment adds Section 309.09 with performance criteria for data centers and accessory uses, creating use-specific requirements for development or operation. The supplied sources do not enumerate those criteria. Add Section 309.09 to provide various performance criteria.

Benefits & exceptionsHide benefits & exceptions1
  • The measure adds definitions for “Data Center” and “Data Center Accessory Use” and allows those uses by exception in the M-3 zoning district; they are not permitted automatically and remain subject to the exception process and the measure’s performance criteria. The Council’s description of the permitted uses

Sources

current law · Sharon City
The city rules are in Ordinance No. 08-2026, which City Council adopted on August 19, 2026, and the county standards are in Mercer County Ordinance No. 2026-003, enacted on July 30, 2026, while a proposed new citywide zoning ordinance, No. 10-26, whose posted August 2026 draft lists data centers as a special exception in the L-I, H-I, and S-I districts, was scheduled for a public hearing and first reading on October 21, 2026.Sharon City, Mercer County — data-center ordinance 08-2026 (2026-08-19)

What this means

The measure imposes cooling and water-use rules, money set aside for eventual removal and noise limits and sound testing. Data centers can still be approved, but these obligations meaningfully increase construction, compliance or review costs.

Benefits & exceptionsHide benefits & exceptions1
  • Approval pathway: Sharon allows data centers only by special exception in the M-3 zoning district, at least 200 feet from residential districts and uses, schools, child care centers, parks, hospitals, and churches, with a 67 dBA day and 57 dBA night noise limit, closed-loop cooling, limits on generator testing, and decommissioning security, and the Mercer County subdivision ordinance adds site standards such as a 60-foot height limit and a 50-foot landscaped buffer. The city rules are in Ordinance No. 08-2026, which City Council adopted on August 19, 2026, and the county standards are in Mercer County Ordinance No. 2026-003, enacted on July 30, 2026, while a proposed new citywide zoning ordinance, No. 10-26, whose posted August 2026 draft lists data centers as a special exception in the L-I, H-I, and S-I districts, was scheduled for a public hearing and first reading on October 21, 2026.

Sources

pending · Sharon City
Its August draft lists data centers as a special exception in the L-I, H-I and S-I districts.Sharon City, Mercer County — ordinance 10-26 (2026-10-21)

What this means

The proposal would provide a route for data centers through a special permit or conditional-use review in designated districts. That offers legal certainty, but the extra approval step can add time and uncertainty.

Benefits & exceptionsHide benefits & exceptions1
  • Proposed approval pathway: Sharon proposed new citywide zoning Ordinance 10-26, with a hearing and first reading listed October 21, 2026. Its August draft lists data centers as a special exception in the L-I, H-I and S-I districts. Adoption has not been established.