City of Springdale

Anti-Data Center Policies

Springdale’s zoning code does not specifically list data centers, so projects may need a city decision or zoning change. Approval can involve development review, added costs, delays, and industrial-district standards, but is not ruled out.

current law · City of Springdale
Requires data center proposals to undergo Springdale’s ordinary zoning review; the code has no data-center-specific rules, so city officials determine which listed use and zoning district apply.Springdale Chapter 153 Zoning Code

What this means

The code does not name data centers, and says uses not specifically permitted are prohibited, so an applicant may need a city determination or zoning change. If approved, a project would still face development review and industrial-district standards, adding real paperwork, costs, and potential delay, but the code provides possible approval routes rather than an outright ban.

People behind it

  • May initiate zoning text or map amendments; reviews them and makes recommendations to City Council.

  • May petition to initiate a zoning text or map amendment and submit development review applications.

  • May initiate or refer zoning amendments and has authority to make decisions on them.

Show 2 more peopleShow fewer people
  • May initiate development review applications.

  • Receives and reviews applications, determines completeness, refers matters for review, issues permits and certificates, and enforces the zoning code.

Restrictions & requirementsHide restrictions & requirements5
  • The code does not specifically list data centers. It prohibits uses not specifically permitted in a zoning district; an unlisted use may be reviewed as a similar use, and the Building Official may find that it is incompatible with every existing district and not permit it. That decision may be appealed to the Planning Commission. Unlisted uses are prohibited and may be found incompatible.

  • Projects subject to development-plan review must submit a complete application and plan drawings; the plan must be prepared by a certified planner, engineer, landscape architect, or architect. The Planning Commission may approve, conditionally approve, or deny the plan. Review applies to development or site/use changes that are not exempt; specified exemptions include certain small non-residential expansions and changes of use in non-residential buildings. Development-plan review requirements and exemptions.

  • If a project requires Planning Commission review, the city’s application instructions require a Planning/Zoning Application plus the relevant minor- or major-project submission packet. Documents are due about 36 days before the meeting, and incomplete or late packets will not be accepted. Required application materials and submittal deadlines.

  • A zoning text or map amendment, including a rezoning, requires Planning Commission review and a public hearing, followed by City Council review and a public hearing and decision. This applies when a project needs such an amendment; it is not a separate approval requirement for every project. Amendment review and hearings.

  • Applications under the zoning code require a filing fee and may require a deposit for estimated city review expenses. The deposit is capped at $5,000 at any time; the city may request another deposit when the balance falls to 33%. Projects with estimated city costs below $500 may not require a deposit. The city adds 10% to final expenses for staff review. Application fees and deposits.

Benefits & exceptionsHide benefits & exceptions4
  • If a data center qualifies as an industrial use, the General Industrial (GI) district allows industrial uses, including manufacturing, warehousing, and production, subject to the code’s standards. Those standards include requirements addressing emissions, noise, vibration, and other impacts. GI industrial-use listing

  • A Planned Unit Development (PUD) may include uses permitted in the GI district when they are consistent with the PUD’s purposes and compatible with the approved plan. The Planning Commission may modify certain setbacks and approve higher density; a PUD generally must cover at least three contiguous acres, with an exception for qualifying smaller sites. PUD uses and flexibility

  • A Transition Overlay District (T-District) plan may allow industrial facilities, including where the plan provides for a mix of uses. This requires Planning Commission review and City Council approval, and the proposal must meet compatibility, buffering, and adopted-plan criteria. T-District industrial uses

  • A lawful existing use may continue if later zoning rules make it nonconforming, providing a limited protection against future restrictions. The protection ends if the use is discontinued for six months; nonconforming uses generally may not be enlarged or extended. Continuation and limits on nonconforming uses