Town of Hildebran
This restriction takes precedence while in effect. The rating below excludes temporary restrictions.
Slightly Pro-Data Center Policies
Hildebran’s enacted rules pause new data-center approvals for a year; afterward, projects need conditional zoning and must meet siting, noise, utility, and cleanup standards, though one description uses conditional wording about enactment.
Rating from North Carolina statewide as there are no scored current or future laws outside temporary restrictions for Town of Hildebran.
current law · Town of HildebranPauses approvals for new data-center projects for one year while the town reviews its rules; data centers must also obtain conditional zoning approval and meet requirements for location, noise, water, utilities, security, and cleanup.Town of Hildebran permanent zoning ordinance for data centers and critical digital infrastructure facilities (adopted March 11, 2026) — responsible official: Town of Hildebran; Town Manager Shook identified in reporting
What this means
The measure would stop new development approvals for data centers for 12 months, a major delay that could block projects during that period (temporary moratorium on development approvals). Afterward, the town’s zoning rules would still require conditional approval and impose strict site and operating standards.
Timing
- Ends
- 12 months after adoption
The Town Council approved a temporary 12-month moratorium on development approvals for critical digital infrastructure facilities. The sources do not provide the moratorium ordinance’s full text or state any extension conditions.
People behind it
- Town Council
Held the public hearings and considered and approved the zoning text amendments and the temporary moratorium on development approvals for critical digital infrastructure facilities.
Restrictions & requirementsHide restrictions & requirements21
A 12-month moratorium was approved on development approvals for critical digital infrastructure facilities, meaning the Town would not approve new permits for covered facilities during the moratorium period. (12-month moratorium)
Critical digital infrastructure facilities may be established only through conditional zoning, rather than ordinary zoning approval. The process requires a master plan, supporting text, Planning Board review, and Town Council approval with mutually agreed conditions. (established through the application and approval process of Conditional Zoning)
The facility must be at least 50 feet from all property lines, 500 feet from residential dwelling units, and 1,000 feet from schools, hospitals, and assisted-living facilities.
A continuous evergreen vegetative buffer at least 20 feet wide must be maintained along all property lines, recorded as a required landscape buffer, and kept in good condition.
Cargo containers, railroad cars, semi-truck trailers, and similar outdoor storage containers or open-air structures may not be used for any component of the facility's operation.
Noise from all facility operations and equipment may not exceed 55 dBC and 40 dBA at any property line at any time.
Applications must include a professional-engineer sound study covering normal operation, generator testing, emergency operation, equipment specifications, and each construction phase. Actual sound levels must be measured within 90 days after occupancy and every two years thereafter, with corrective action required within 90 days if limits are exceeded.
The facility may not produce ground-transmitted vibration that is discernible without instruments beyond the property line, and particle velocity may not exceed 2 inches per second or other Town-approved industry standards.
Applications must include a vibration impact study, and actual vibration levels must be measured within 90 days after occupancy and every two years thereafter. Corrective action is required within 90 days if limits are exceeded.
On-site generators must meet Tier 4 or equivalent emissions standards and may not be the primary or sole source of normal operating power.
Generator testing is limited to Monday through Friday from 8:00 a.m. to 5:00 p.m.; generally, only one generator per building, or the minimum necessary number, may be tested at a time for no more than 60 minutes. Permanent generators must be enclosed or placed in sound-proofed or acoustically treated enclosures.
Applicants must submit a water-use and conservation plan identifying normal and peak demand, water-saving measures, and impacts on public water systems and watershed requirements.
Before a zoning permit, applicants using public electricity, potable water, or sanitary sewer must obtain written provider verification that sufficient capacity and infrastructure exist, or will be upgraded, without materially harming existing service.
The applicant is responsible for electrical-system improvements or infrastructure upgrades needed to serve the facility.
The entire facility boundary must be fenced with a minimum six-foot fence. Chain-link and barbed-wire fencing are prohibited along public or private street frontages; decorative metal, masonry, or Town-approved materials are required there.
Facility lighting must be fully shielded and directed downward so it does not create glare or illuminate adjacent properties or public rights-of-way.
Electronic waste must be handled by a North Carolina Department of Environmental Quality-licensed electronic-waste recycling firm.
No structures, equipment, storage, or buildings associated with the facility may be located in a Special Flood Hazard Area.
Any expansion that increases building floor area, electrical demand, mechanical-equipment capacity, or operational intensity requires prior review and approval under the critical digital infrastructure standards.
If the facility ceases operation for 12 continuous months, the use is considered discontinued, and the owner must remove equipment, generators, fuel-storage systems, machinery, and related operational infrastructure within a Town-approved timeframe. Reestablishment requires new approval.
A conditional-zoning application must include a decommissioning and site-restoration plan, and a financial assurance must be provided before a zoning permit. The assurance must equal 1.25 times estimated decommissioning cost minus 50% of salvageable value, or $75,000, whichever is greater, and must be reevaluated every four years or after an expansion.
Benefits & exceptionsHide benefits & exceptions8
Critical Digital Infrastructure Facilities, including data centers and cryptocurrency-mining facilities, are recognized as an eligible use and may be approved through conditional zoning rather than being categorically prohibited.
A conditional-zoning application may be initiated voluntarily by the property owner or authorized agent and may establish a project-specific master plan, permitted uses, development standards, and mutually agreed conditions governing the facility.
After conditional-zoning approval, the approved master plan and conditions become the zoning regulations for the property, providing a defined framework for development and operation.
Minor changes to an approved conditional-zoning project may be approved administratively, including up to a 10% or 1,000-square-foot increase in nonresidential intensity, whichever is less, up to a 10% increase in residential density, or limited changes to street alignment and lot configuration.
The ordinance provides an express process for facility expansion: any increase in building floor area, electrical demand, mechanical-equipment capacity, or operational intensity may proceed after review and approval under the critical-infrastructure standards.
A facility may continue operating during temporary interruptions because it is not considered discontinued until it has ceased operation continuously for 12 months; reestablishment after that period requires new approval.
Emergency generators are allowed for emergency power, testing, maintenance, and other limited operational scenarios, and generator testing is expressly authorized during specified weekday hours.
The ordinance creates a utility-capacity review process under which an applicant can obtain written verification from electric, water, and sewer providers that adequate capacity exists or can be made available through upgrades, subject to the applicant's responsibility for required electrical-system improvements.
Sources
current law · Town of HildebranTemporarily bars new development approvals for data centers and similar facilities for one year; otherwise, they require conditional zoning approval and must meet detailed siting, noise, water, utility, and decommissioning requirements.Town of Hildebran temporary moratorium on critical digital infrastructure facilities (adopted August 24, 2026) — responsible officials: Hildebran Town Council; unanimous adoption reported
What this means
If enacted, the one-year pause on new development approvals would prevent new data center projects from moving forward during that period (no new permits for the next year). The zoning rules would also require conditional approval and impose substantial requirements for siting, noise, utilities, and eventual cleanup (facilities are established through conditional zoning).
Timing
- Ends
- 12 months after adoption
The Town Council approved a temporary moratorium on development approvals for critical digital infrastructure facilities. The minutes describe it as a 12-month moratorium during which no new permits would be approved. The ordinance text and any extension conditions are not included in the provided sources.
People behind it
- Town Council of the Town of Hildebran
Adopted the temporary moratorium on development approvals for critical digital infrastructure facilities.
- Ben Honeycutt
Introduced the motion to approve the temporary moratorium ordinance.
- Western Piedmont Council of Governments
Prepared the Town’s zoning ordinance containing the critical digital infrastructure facility regulations.
Show 1 more peopleShow fewer people
- Town of Hildebran Planning Board
Worked with the Western Piedmont Council of Governments in preparing the zoning ordinance.
Restrictions & requirementsHide restrictions & requirements17
The Town Council approved a temporary moratorium on development approvals for critical digital infrastructure facilities. The minutes state that, if adopted, the Town would approve no new permits for the next year. no new permits for the next year
A data center, cryptocurrency-mining facility, or similar critical digital infrastructure facility may be established only through conditional zoning, requiring approval under the conditional-zoning process and an approved major site plan. established through the application and approval process of Conditional Zoning
Outdoor cargo containers, railroad cars, semi-truck trailers, and similar open-air storage structures cannot be used for any component of the facility's operation. prohibited
Structures must be at least 50 feet from all property lines, 500 feet from residential dwelling units, and 1,000 feet from schools, hospitals, and assisted-living facilities. setback requirements
A continuous evergreen vegetative buffer at least 20 feet wide, designed to grow at least six feet high, must be maintained along all property lines and recorded as a required landscape buffer. continuous 20-foot wide
Facility noise may not exceed 55 dBC and 40 dBA at any property line at any time. Applications must include an acoustical sound study, and actual sound levels must be tested within 90 days after occupancy and every two years thereafter. Exceedances require corrective action within no more than 90 days and can result in suspension or revocation of the zoning certificate. maximum combined sound pressure levels
Facilities may not produce discernible ground-transmitted vibration beyond the property line or vibration exceeding two inches per second particle velocity. A vibration-impact study and testing within 90 days after occupancy and biennially thereafter are required, with corrective action required for exceedances. No vibration may be produced
Generators must meet Tier 4 or equivalent emissions standards, cannot be the primary or sole source of normal operating power, and generator testing is generally limited to Monday through Friday from 8:00 a.m. to 5:00 p.m., with only one generator per building tested at a time for no more than 60 minutes. Permanent generators must be enclosed or placed in sound-proofed or acoustically treated enclosures. Generators must meet or exceed Tier 4
Applicants must submit a water-use and conservation plan addressing normal and peak demand, potable-water reduction measures, and impacts on the public water system and watershed requirements. water use and conservation plan
Before a zoning permit, applicants using public utilities must obtain written verification of adequate electrical, potable-water, and sanitary-sewer capacity and infrastructure. Required electrical upgrades are the applicant's responsibility. Any system improvements or infrastructure upgrades
The entire property must be fenced with a minimum six-foot fence. Chain-link and barbed-wire fencing are prohibited along public or private street frontages, requiring decorative metal, masonry, or other Town-approved materials. minimum six-foot height
Lighting must be fully shielded and directed downward so it does not create glare or illumination on adjacent properties or public rights-of-way. fully shielded and directed downward
Electronic waste must be handled by a North Carolina Department of Environmental Quality-licensed electronic-waste recycling firm. licensed electronic waste recycling firm
No structures, equipment, storage, or buildings may be located within a Special Flood Hazard Area. No structures, equipment, storage, or buildings
Any expansion that increases building floor area, electrical demand, mechanical-equipment capacity, or operational intensity requires prior Town review and approval. Any expansion
If operations cease continuously for 12 months, the use is considered discontinued and the owner must remove equipment, machinery, generators, fuel-storage systems, and related infrastructure within a Town-approved timeframe; reestablishment requires new approval. ceases operation for a continuous period of twelve (12) months
A decommissioning and site-restoration plan is required, along with financial assurance before issuance of a zoning permit. The assurance must equal 1.25 times estimated decommissioning costs minus 50% of salvageable value, or $75,000, whichever is greater. financial assurance
Benefits & exceptionsHide benefits & exceptions7
Critical Digital Infrastructure Facilities—including data centers and cryptocurrency-mining facilities—are allowed in the General Manufacturing District through the conditional-zoning process, rather than being categorically prohibited. The use requires an approved conditional zoning and site plan. Critical Digital Infrastructure Facility (see Section 10.10) PC
Once conditional zoning is approved, the approved conditional zoning, master plan, and site plan govern the facility's development and use, providing an established approval framework for construction. An approved conditional zoning and the approved site plan shall govern all uses and development activities
Expansion of a Critical Digital Infrastructure Facility is expressly authorized as a development pathway. Expansion may increase building floor area, electrical demand, mechanical-equipment capacity, or operational intensity, but it requires prior Town review and approval under the facility standards.
Projects that had already been built or had established vested rights before the zoning ordinance took effect are treated as existing development. This includes projects with substantial expenditures made in good-faith reliance on approval, a valid building permit, or an approved site-specific or phased development plan.
Existing development is exempt from the watershed-protection requirements. Expansions of existing structures must comply with the watershed rules, but the existing built-upon area does not have to be included in density calculations.
A lawful nonconforming facility or use may continue even if later zoning rules would prohibit it. The protection is limited: the use generally may not be enlarged, and it can lose nonconforming status after 180 consecutive days of discontinued operation.
Approved site-specific or planned-unit-development plans receive a vested period exceeding two years but not more than five years, and approved multi-phase developments of at least 25 acres receive seven years of vesting. This can protect an approved data-center project from later zoning changes during those periods.